Module "CLT-Plate 1D - Continuous beam"
39 Treffer, Zuletzt geändert:
ncluding a cantilever on the left and right side can be analysed. The supporting width and span of field (via x-value in the table) can be defined within this input field. {{ en:clt:hotspot:softwa... tem}} ==== Cross section ==== The cross section can be defined by the user or by choosing a typical c
Module "Horizontal load distribution on shear walls"
10 Treffer, Zuletzt geändert:
l forces ==== The quantity of horizontal forces can be specified by entering H<sub>x</sub> and H<sub>y</sub> in [kN]. The position of the forces can be either user-defined (H<sub>x</sub> along the l... oben_button.png?40&nolink|}}, the selected point can be moved up in the sequence. * By clicking {{:c... nten_button.png?40&nolink|}}, the selected point can be moved down in the sequence. {{ en:clt:hotspot
Module "Wall"
10 Treffer, Zuletzt geändert:
only rectangular wall elements without openings can be calculated. The wall is defined via a wall hei... tered, are at design level. The following loads can be applied: * vertical load q<sub>d</sub> * h... esign factors}} Should it be necessary to define an eccentric load application of q<sub>d</sub>, the input of e<sub>qd</sub> can be displayed by pressing the button {{:en:clt:hot
Module "Compression perpendicular to grain"
6 Treffer, Zuletzt geändert:
pe of load configuration * calculation options An option for a quick control of the input data is o... * possible occurrence of gaps or cracks wider than 1 mm. ==== Load data and design factors ==== The... ign value) in [N], as well as the design factors can be specified here. {{ en:clt:hotspot:software:cl... load introduction above and below. Thereby, one can define if the load is even applied, and if so, if
Module "SHERPA CLT-Connector"
6 Treffer, Zuletzt geändert:
a warning message is displayed and, if possible, an alternative screw length is mentioned. {{ en:clt... be connected). The length of the inclined screws can be 100 mm, 120 mm or 140 mm, depending on require... rs such as compriband or sound insulation layers can be placed between the elements. Since the install... on wall-floor", wall height and length as well as an edge distance must be specified. When selecting t
Module "Ribbed slab"
4 Treffer, Zuletzt geändert:
tural system ==== In this release, only single span girder can be calculated. The supporting width and span (via x-value in the table) can be defined within this input field. {{ en:clt:hotspot:software:cltdes
Module "Stiffness matrix"
2 Treffer, Zuletzt geändert:
iffness_matrix:ergebnisse_steifigkeitsmatrix_membran.png |Stiffness matrix - Parts for loading in-plan... rt.png |Contents of the csv file}} The csv file can be imported into RFEM 5 via "Edit Surface" and th