- Module "Horizontal load distribution on shear walls" @en:clt:hotspot:software:cltdesigner:manual
- ====== Module "Horizontal load distribution on shear walls" ====== {{ en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:gesamtgebaeudeaussteifung.png?600 |Module Horizontal load distribution on shear walls}} ===== Input data ===== The input ... signer:manual:modul_horizontal_force_distribution_on_shear_walls:gebaeudeaussteifung_kraefte.png |Inpu
- Module "CLT-Plate 1D - Continuous beam" @en:clt:hotspot:software:cltdesigner:manual
- aphical representation of the input data is shown on the right side. This offers the possibility for a... with a maximum of 7 spans including a cantilever on the left and right side can be analysed. The supp... f the CLT plate is calculated automatically based on the thickness of the single layers. The ratio of... rieved by selecting "My CLT cross sections" later on. The library can be displayed with the button {{
- CLTdesigner User manual @en:clt:hotspot:software:cltdesigner
- *Base documents:** * **DIN EN 1990:2010-12 and ON EN 1990:2003-03 respectively:**\\ Basis of structural design * **DIN EN 1991-1-1:2010-12 and ON EN 1991-1-1:2003-03 respectively:**\\ Actions on structures\\ Part 1-1: General actions – Densities... s for buildings * **DIN EN 1995-1-1:2010-12 and ON EN 1995-1-1:2009-07 respectively:**\\ Design of
- CLTdesigner - Versions and changes @en:clt:hotspot:software:cltdesigner
- s Hasslacher\\ - Displaying the storage location on the window\\ - Output of the deflection in mm in... mm/Richter mod.\\ - vibration check according to ON B extended by vibration acceleration\\ - layups ... e for Hasslacher changed\\ - problem with tables on Mac fixed\\ - SLS combination problem with wind ... |- Binder and Stora Enso layups included\\ - ON B1995-1-1:2014 implemented\\ - disregarding of s
- Module "SHERPA CLT-Connector" @en:clt:hotspot:software:cltdesigner:manual
- lection of screw length * options * depending on the connection type further system specifications... == Screws ==== The SHERPA CLT-Connector is fixed on element 1 (base element) at the factory by using ... screws can be 100 mm, 120 mm or 140 mm, depending on requirements. {{ en:clt:hotspot:software:cltdesi... ==== Load data and design factors ==== Depending on the selected connection type, either loads (conne
- Instructions for download and installation @en:clt:hotspot:software:cltdesigner
- signer}} After successful registration and login on the website, the [[http://www.cltdesigner.at/inde... ava.png?300 |Windows Control Panel}} By clicking on it, the Java Control Panel is shown. Afterwards, ... designer in the Java Cache Viewer and by clicking on the green start button an online search for updates on the CLTdesigner is started. If an updated version
- Module „CLT-Plate 1D - Internal forces“ @en:clt:hotspot:software:cltdesigner:manual
- heory (of 1<sup>st</sup> or 2<sup>nd</sup> order) on which the calculations are based on * design factors * specifications concerning stability ==== C... e internal forces result from a calculation based on a first order analysis a substitute buckling leng... tive normal force ("problem of stability"). Based on this buckling length and the respective cross sec
- CLTdesigner - Implemented calculation methods @en:clt:hotspot:software:cltdesigner
- esign:plate_loaded_in_plane:local_load:local_load_on_wall|Lasteinleitung in Wandscheiben aus BSP – Bes... esign:plate_loaded_in_plane:local_load:local_load_on_wall_short|Ermittlung der wirksamen Lastverteilbr... BSP]] ===== Module "Horizontal load distribution on shear walls" ===== * [[clt:design:building_system:horizontal_load_distribution_on_shear_walls|Aufteilung von Horizontallasten auf W
- Module "Compression perpendicular to grain" @en:clt:hotspot:software:cltdesigner:manual
- ta is offered by a graphical representation shown on the right side. {{ en:clt:hotspot:software:cltde... c,90</sub>. For different load introduction areas on each side it is the intersection of these two are
- Module "CLT-Plate loaded in plane" @en:clt:hotspot:software:cltdesigner:manual
- as the design factors. The design method is based on a board width which is chosen when defining the c... he utilization ratios, that were calculated based on ETA-08/242 [(:ref:eta_08_0242_2009)] and ETA-09/0
- Module "Wall" @en:clt:hotspot:software:cltdesigner:manual
- he permanent vertical load has a relieving effect on the anchor force, this is reduced by multiplicati... existing fasteners in the floor joint. Depending on the selected calculation model, different inputs
- Module "Stiffness matrix" @en:clt:hotspot:software:cltdesigner:manual
- ity}} ==== Export possibilities ==== By clicking on the button {{en:clt:hotspot:software:cltdesigner: