en:clt:hotspot:software:cltdesigner:manual:modul_wall [2021/05/17 15:44] – created Alexandra Thielen:clt:hotspot:software:cltdesigner:manual:modul_wall [2021/07/22 14:21] (current) – [Connection wall floor] Alexandra Thiel
Line 8: Line 8:
   * wall dimensions and boundary conditions   * wall dimensions and boundary conditions
   * cross section   * cross section
-  * design loads and design factors (cold and in case of fire)+  * design loads and design factors
   * stability   * stability
   * connection wall floor   * connection wall floor
Line 98: Line 98:
 {{ :en:clt:hotspot:software:cltdesigner:manual:modul_wall:wall_floor_connection_cont.png |Tension, compression, shear continuously}} {{ :en:clt:hotspot:software:cltdesigner:manual:modul_wall:wall_floor_connection_cont.png |Tension, compression, shear continuously}}
  
 +**Spring model**
 +
 +In this model, tensile and shear spring stiffnesses of discretely arranged fasteners can be entered as well as a distribution width for the respective stress direction. The contact (compressive stress) is taken into account by means of an elastic bedding (input of the bedding factor c in kN/m/m).
 +
 +{{ :en:clt:hotspot:software:cltdesigner:manual:modul_wall:wall_floor_connection_spring_model.png?700 |Spring model}}
 ==== Fire ==== ==== Fire ====
  