en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam [2020/03/24 11:38] – [Optimization of layup] Alexandra Thielen:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam [2020/03/24 12:44] – [Fire] Alexandra Thiel
Line 94: Line 94:
 === Optimization of layup === === Optimization of layup ===
  
-Use the button {{en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam:show_cs_optimization_button.png?130&nolink}} to display the window for layup optimization.+Use the button {{en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam:show_cs_optimization_button.png?170&nolink}} to display the window for layup optimization.
  
 {{ en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam:cs_optimization.png?600 |Layup optimization}} {{ en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam:cs_optimization.png?600 |Layup optimization}}
Line 136: Line 136:
 ==== Fire ==== ==== Fire ====
  
-By choosing "Fire above" and/or "Fire below" in the tab "Fire" a structural fire design has to be carried out. The "Fire duration" is specified in minutes and can be increased (or decreased) by increments of 30 minutes by pressing the up (or down) arrows, or defined by entering a specific duration between 0 minutes and 240 minutes in the allotted box. By ticking the box next to "Fire protection" a layer of fire protection is added to the plate, but the effective protection time of the protection layer needs to be defined.+By choosing "Fire above" and/or "Fire below" in the tab "Fire" a structural fire design has to be carried out. The "Fire duration" is specified in minutes and can be increased (or decreased) by increments of 30 minutes by pressing the up (or down) arrows, or defined by entering a specific duration between 0 minutes and 240 minutes in the allotted box. By ticking the box next to "Fire protection system" a layer of fire protection is added to the plate. Furthermore, the position ("above" and/or "below") must be declared and the parameters t<sub>ch</sub>, t<sub>f</sub>, k<sub>2</sub> and k<sub>3</sub> must be specified. In case the failure time of the fire protection system is equal to the time until the protected component starts to burn, the option "t<sub>f</sub> = t<sub>ch</sub>" shall be checked.
  
 {{ en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam:fire.png |Input - Fire}} {{ en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam:fire.png |Input - Fire}}
  • en/clt/hotspot/software/cltdesigner/manual/modul_plate1d_continuousbeam.txt
  • Last modified: 2020/10/28 10:01
  • by Alexandra Thiel