en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls [2017/12/12 18:44] – [Options] kbratulicen:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls [2020/03/26 11:44] (current) Alexandra Thiel
Line 1: Line 1:
-FIXME **This page is not fully translated, yet. Please help completing the translation.**\\ //(remove this paragraph once the translation is finished)// 
- 
 ====== Module "Horizontal load distribution on shear walls" ====== ====== Module "Horizontal load distribution on shear walls" ======
  
Line 13: Line 11:
   * input of the shear walls   * input of the shear walls
   * calculation options   * calculation options
 +
 ==== Horizontal forces ==== ==== Horizontal forces ====
  
-The quantity of horizontal forces can be specified by entering H<sub>x</sub> and H<sub>y</sub> in [kN]. The position of the forces can be either unser-defined (H<sub>x</sub> along the line of action in y<sub>Hx</sub> and H<sub>y</sub> along the line of action in x<sub>Hy</sub>) or specified at the center of mass. By selecting "at center of mass", the position of the forces will be determined from the polygon of floor.  +The quantity of horizontal forces can be specified by entering H<sub>x</sub> and H<sub>y</sub> in [kN]. The position of the forces can be either user-defined (H<sub>x</sub> along the line of action in y<sub>Hx</sub> and H<sub>y</sub> along the line of action in x<sub>Hy</sub>) or specified at the center of mass. By selecting "at center of mass", the position of the forces will be determined from the polygon of floor.  
  
 {{ en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:gebaeudeaussteifung_kraefte.png |Input of the horizontal acting forces}} {{ en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:gebaeudeaussteifung_kraefte.png |Input of the horizontal acting forces}}
Line 33: Line 32:
 ==== Walls ==== ==== Walls ====
  
-FIXME +The walls can be defined using the following table. The selection of the cross-section, and thereby of the producer, is in the current calculation neglected since the stiffnesses are calculated in proportion to the wall length. The position of the wall can be defined either by specifying the reference point (in the draft above, the point is set in the lower left corner at the φ = 0°; x<sub>ref</sub> and y<sub>ref</sub>) or by entering the center of mass (x<sub>C</sub> and y<sub>C</sub>), as well as the angle of rotation φ.
-The walls can be defined using the following table. The selection of the cross-section, and thereby of the producer, is in the current calculation neglected since the stiffnesses are calculated in proportion to the wall length. The position of the wall can be defined either by specifying the reference point (in the draft above, the point is set in the lower left corner at the φ = 0°; x<sub>ref</sub> and y<sub>ref</sub>) or by entering the center of mass (gravity???(x<sub>C</sub> and y<sub>C</sub>), as well as the angle of rotation φ+
- +
-Die Eingabe der Wände kann in folgender Tabelle vorgenommen werden. Die Auswahl des Querschnittes und somit des Produzenten ist in der derzeitigen Berechnung unerheblich, da die Steifigkeiten nur proportional zur Wandlänge berechnet werden. Die Lage der Wände wird entweder über die Eingabe des Bezugspunktes (Punkt links unten bei φ = 0°; x<sub>ref</sub> und y<sub>ref</sub>) oder über Eingabe des Schwerpunktes (x<sub>C</sub> und y<sub>C</sub>) sowie dem Drehwinkel φ beschrieben.+
  
 {{ en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:gebaeudeaussteifung_waende.png |Input of shear walls}} {{ en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:gebaeudeaussteifung_waende.png |Input of shear walls}}
Line 42: Line 38:
   * By clicking {{:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:plus_button.png?40&nolink|}}, a new wall can be created.   * By clicking {{:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:plus_button.png?40&nolink|}}, a new wall can be created.
   * By clicking {{:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:minus_button.png?40&nolink|}}, the selected wall will be deleted.   * By clicking {{:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:minus_button.png?40&nolink|}}, the selected wall will be deleted.
- 
-  * Mit {{:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:plus_button.png?40&nolink|}} kann eine neue Wand erzeugt werden. 
-  * Mit {{:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:minus_button.png?40&nolink|}} wird die selektierte Wand gelöscht. 
 ==== Options ==== ==== Options ====
  
-FIXME +In the current version, the stiffness of the wall systems c is calculated proportional to the wall length (c ∼ ℓ<sup> exp</sup>). The exponent exp can be specified here.
-In the current version, the stiffness of the wall (with wall fixation) is calculated proportionally over the wall length (??) (c ∼ ℓ<sup> exp</sup>). The exponent exp can be specified here+
- +
-In der derzeitigen Version erfolgt die Berechnung der Wandsteifigkeiten (Wand inkl. Befestigung) proportional über die Wandlänge (c ∼ ℓ<sup> exp</sup>). Der Exponent exp kann hier eingestellt werden.+
  
 {{ en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:gebaeudeaussteifung_optionen.png |Calculation options}} {{ en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:gebaeudeaussteifung_optionen.png |Calculation options}}
Line 60: Line 50:
 ==== Output of the forces acting on the walls ==== ==== Output of the forces acting on the walls ====
  
-Die Ausgabe erfolgt getrennt für die angreifenden Kräfte H<sub>x</sub> und H<sub>y</sub> sowie für die Kombination H<sub>x</sub> + H<sub>y</sub>Ausgegeben wird jeweils das Momentwelches sich aus einem exzentrischen Lastangriff ergibt sowie die Kräfte auf die einzelnen Wände in ihren x- und y-Komponenten (F<sub>x</sub> und F<sub>y</sub>sowie als Resultierende unter dem Winkel α<sub>F</sub>Zur Kontrolle werden auch noch die Summe der Kräfte in x- bzw. y-Richtung sowie die Summe der Momente überprüft.+The output is given separately for the acting forces H<sub>x</sub> and H<sub>y</sub> and the combination H<sub>x</sub> + H<sub>y</sub>The output comprises the momentresulting from the load eccentricity, as well as the forces acting on each wall defined with their components and y (F<sub>x</sub> and F<sub>y</sub>and also the resulting force at the angle α<sub>F</sub>As a control, the sum of the forces in x and direction, as well as the sum of the moments are verified as well
  
 {{en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:kraefte_zufolge_hx_und_hy.png|Forces according to Hx and Hy}} {{en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:kraefte_zufolge_hx_und_hy.png|Forces according to Hx and Hy}}
  
-Eine graphische Darstellung der Ergebnisse ist im Fenster rechts unten zu sehen, wieder unterteilt in H<sub>x</sub>, H<sub>y</sub> und H<sub>x</sub> + H<sub>y</sub>.+A graphic representation of the results is also divided into H<sub>x</sub>, H<sub>y</sub> and H<sub>x</sub> + H<sub>y</sub> and can be seen in the lower right corner of the window
  
 {{en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:ergebnisse_zufolge_hx_und_hy.png?600|Results according to Hx and Hy}} {{en:clt:hotspot:software:cltdesigner:manual:modul_horizontal_force_distribution_on_shear_walls:ergebnisse_zufolge_hx_und_hy.png?600|Results according to Hx and Hy}}
Line 70: Line 60:
 ===== Implemented calculation methods ===== ===== Implemented calculation methods =====
  
-++++ Modellierung als starre Deckenscheibe und Wände als Wegfedern |+++++ Modeling as rigid floor plate and walls as extensional springs |
 {{page> :clt:design:building_system:horizontal_load_distribution_on_shear_walls:model_with_springs&inline&permalink&noheader}} {{page> :clt:design:building_system:horizontal_load_distribution_on_shear_walls:model_with_springs&inline&permalink&noheader}}
 ++++ ++++
 +
 +~~DISCUSSION~~
  • en/clt/hotspot/software/cltdesigner/manual/modul_horizontal_force_distribution_on_shear_walls.1513100641.txt.gz
  • Last modified: 2017/12/12 18:44
  • by kbratulic