en:clt:hotspot:software:cltdesigner:manual

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revisionBoth sides next revision
en:clt:hotspot:software:cltdesigner:manual [2021/07/22 15:50] Alexandra Thielen:clt:hotspot:software:cltdesigner:manual [2022/05/04 14:09] – [Settings/Preferences] Alexandra Thiel
Line 43: Line 43:
 ==== Modules ==== ==== Modules ====
  
-Currently the CLTdesigner consists of modules.+Currently the CLTdesigner consists of modules.
  
 The [[en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam|Module „CLT-Plate 1D - Continuous beam“]] offers the required verifications for the ultimate limit state (ULS) with respect to bending and shear for permanent and transient loads as well as accidental (fire) design situations, and the verifications for the serviceability limit state with respect to deflection and vibrations according to EN 1990 or EN 1995 for continuous systems such as cross laminated timber plates. The [[en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam|Module „CLT-Plate 1D - Continuous beam“]] offers the required verifications for the ultimate limit state (ULS) with respect to bending and shear for permanent and transient loads as well as accidental (fire) design situations, and the verifications for the serviceability limit state with respect to deflection and vibrations according to EN 1990 or EN 1995 for continuous systems such as cross laminated timber plates.
Line 122: Line 122:
 It is also necessary to specify whether the National Annex should be considered in verification and if so, which one. Furthermore, partial safety factors for the ULS verification need to be specified by selecting either EN, NA or user-defined from a drop-down list. It is also necessary to specify whether the National Annex should be considered in verification and if so, which one. Furthermore, partial safety factors for the ULS verification need to be specified by selecting either EN, NA or user-defined from a drop-down list.
  
-{{ en:clt:hotspot:software:cltdesigner:manual:preferences_verification_uls.png |Preferences - Verification - ULS}}+{{ en:clt:hotspot:software:cltdesigner:manual:preferences_verification_uls.png?675 |Preferences - Verification - ULS}}
  
 The deformation factors (values according to either TU Graz, EN, NA or user-defined), as well as the limit values for deformation need to specified in the "Deformations" tab within the subsection regarding the SLS verification. By ticking the first box, the weight of the plate g<sub>0</sub> will not be considered in calculation of instantaneous deformation w<sub>inst</sub> at t=0. Furthermore, here can be also specified whether the Base Document should be taken into account in deformation analysis or not. Likewise, here is also given an option to neglect short cantilevers in deformation analysis.    The deformation factors (values according to either TU Graz, EN, NA or user-defined), as well as the limit values for deformation need to specified in the "Deformations" tab within the subsection regarding the SLS verification. By ticking the first box, the weight of the plate g<sub>0</sub> will not be considered in calculation of instantaneous deformation w<sub>inst</sub> at t=0. Furthermore, here can be also specified whether the Base Document should be taken into account in deformation analysis or not. Likewise, here is also given an option to neglect short cantilevers in deformation analysis.   
  • en/clt/hotspot/software/cltdesigner/manual.txt
  • Last modified: 2022/05/04 14:20
  • by Alexandra Thiel