en:clt:hotspot:software:cltdesigner:manual

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revisionBoth sides next revision
en:clt:hotspot:software:cltdesigner:manual [2021/07/22 15:50] Alexandra Thielen:clt:hotspot:software:cltdesigner:manual [2022/01/24 14:20] – [Modules] Alexandra Thiel
Line 43: Line 43:
 ==== Modules ==== ==== Modules ====
  
-Currently the CLTdesigner consists of modules.+Currently the CLTdesigner consists of modules.
  
 The [[en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam|Module „CLT-Plate 1D - Continuous beam“]] offers the required verifications for the ultimate limit state (ULS) with respect to bending and shear for permanent and transient loads as well as accidental (fire) design situations, and the verifications for the serviceability limit state with respect to deflection and vibrations according to EN 1990 or EN 1995 for continuous systems such as cross laminated timber plates. The [[en:clt:hotspot:software:cltdesigner:manual:modul_plate1d_continuousbeam|Module „CLT-Plate 1D - Continuous beam“]] offers the required verifications for the ultimate limit state (ULS) with respect to bending and shear for permanent and transient loads as well as accidental (fire) design situations, and the verifications for the serviceability limit state with respect to deflection and vibrations according to EN 1990 or EN 1995 for continuous systems such as cross laminated timber plates.
Line 61: Line 61:
 The [[en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector|Module „SHERPA CLT-Connector“]] calculates connections of cross laminated timber elements with the SHERPA CLT-Connector according to the European Technical Assessment ETA-18/0083. The [[en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector|Module „SHERPA CLT-Connector“]] calculates connections of cross laminated timber elements with the SHERPA CLT-Connector according to the European Technical Assessment ETA-18/0083.
  
-The [[clt:hotspot:software:cltdesigner:manual:modul_wall|Module „Wall“]] offers the required verifications for the ultimate limit state (ULS) of walls under vertical and horizontal loads as well as wind perpendicular to the wall plane (cold and hot dimensioning).+The [[en:clt:hotspot:software:cltdesigner:manual:modul_wall|Module „Wall“]] offers the required verifications for the ultimate limit state (ULS) of walls under vertical and horizontal loads as well as wind perpendicular to the wall plane (cold and hot dimensioning).
 ==== Menu bar ==== ==== Menu bar ====
  
  • en/clt/hotspot/software/cltdesigner/manual.txt
  • Last modified: 2022/05/04 14:20
  • by Alexandra Thiel