| Beide Seiten der vorigen Revision Vorhergehende Überarbeitung Nächste Überarbeitung | Vorhergehende Überarbeitung |
| en:clt:hotspot:software:cltdesigner:manual [2024/10/10 16:01] – [Settings/Preferences] Alexandra Thiel | en:clt:hotspot:software:cltdesigner:manual [2024/10/10 18:12] (aktuell) – [Buttons] Alexandra Thiel |
|---|
| {{clt:hotspot:software:cltdesigner:manual:button_groups.png?253|Settings/Preferences, Information and Help}} | {{clt:hotspot:software:cltdesigner:manual:button_groups.png?253|Settings/Preferences, Information and Help}} |
| |
| The first group (from left to right) consist of **Save**, **Save as ...** and **Generate report** (see [[#Menus]]). | The first group (from left to right) consist of **Save**, **Save as ...** and **Generate report** (see [[#Menu bar]]). |
| |
| The next button is **Calculate**. The calculation can also be started with the shortcut CTRL+R. | The next button is **Calculate**. The calculation can also be started with the shortcut CTRL+R. |
| In the modules for rib and box cross-sections, it is also possible to select the calculation method for the effective width. | In the modules for rib and box cross-sections, it is also possible to select the calculation method for the effective width. |
| |
| {{ en:clt:hotspot:software:cltdesigner:manual:preferences_analysis.png |Preferences - Analysis}} | {{ en:clt:hotspot:software:cltdesigner:manual:preferences_analysis.png?475 |Preferences - Analysis}} |
| |
| It is also necessary to specify whether the National Annex should be considered in **verification** and if so, which one. Furthermore, partial safety factors for the **ULS verification** need to be specified by selecting either EN, NA or user-defined from a drop-down list. The user also can specify whether the system coefficient k<sub>sys</sub> should be taken into account or not. For the proof of stability, the imperfection coefficient β<sub>c</sub> and the conversion factor mean value to 5% quantile value k<sub>05</sub> as well as the consideration of the shear deformation can be defined here. | It is also necessary to specify whether the National Annex should be considered in **verification** and if so, which one. Furthermore, partial safety factors for the **ULS verification** need to be specified by selecting either EN, NA or user-defined from a drop-down list. The user also can specify whether the system coefficient k<sub>sys</sub> should be taken into account or not. For the proof of stability, the imperfection coefficient β<sub>c</sub> and the conversion factor mean value to 5% quantile value k<sub>05</sub> as well as the consideration of the shear deformation can be defined here. |